Offering smart stone treatment with a portfolio of innovative, cost-effective solutions that don’t compromise patient care.
The BD Solo™ Plus Guidewire is designed for access to the ureter and maneuverability around stone. With its radiopaque tip, the Solo™ Plus is visible and detectible under fluoroscopic view. The BD Solo™ Plus is also 41% stiffer1 than the leading competition.
BD offers a full line of guidewires including the BD Solo™ Flex and Hydro.
The X-Force™ line of balloon dilation catheters are comprised of a patented multilayer balloon with a rated burst pressure of 30ATM. Utilized in the management of urolithiasis and ureteric strictures, the X-Force™ boasts a radiopaque tungsten tip to aid in radiographic visualization.
The Proxis™ Ureteral Access Sheath combines hydrophilic coating, a smooth dialator-sheath transition, and a large hub to aid in access and introduction of instruments.
The BD Aptra™ Single-Use Digital Flexible Ureteroscope offers image quality enhanced with the light source inside the tip of the scope, tapered 7.4 Fr. distal tip, and maximum deflection designed to reach stones in the lower pole.
The ProFlex™ Laser Fiber is a fiber optic laser delivery system consisting of a patented Pulsarill HPC high power connector on a silica core, double clad fiber.
Constructed of Nitinol, the SkyLite™ Basket offers a kink-resistant design to aid in stone extraction and is designed to perform in a fully deflected flexible ureteroscope.
Stent designed for ease of insertion, navigation around obstacles, and minimized migration. pHreeCoat provides a hydrophobic coating with smooth surface and encrustation resistant properties.
1. Data based on IPSOS report for BD.
2. 0.035" guidewires tested. Boston Scientific Sensor® Dual-Flex tested. Bench data on file with BD. In-vitro data may not correlate to clinical performance.
Intended use
BD Aptra™ Digital Endoscope System is intended to be used by physicians to access, visualize, and perform procedures in the urinary tract and the kidney. The
instrument enables delivery and use of accessories such as biopsy forceps, laser fibers, graspers and retrieval baskets at a surgical site.
Contraindications
Diagnostic or therapeutic ureteroscopy is contraindicated in people with an untreated urinary tract infection.
Other contraindications to therapeutic ureteroscopy (e.g. lithotripsy, endopyelotomy, tumor therapy) are more numerous and can mirror those associated with the
corresponding open surgical interventions. Patients on anticoagulants or with coagulopathies should be managed appropriately.
Warnings
• Do not use electromedical energy sources in the presence of flammable detergents, anesthetics, nitrous oxide (N2O), or oxygen.
• Consult the user manuals of all electromedical energy sources used with endoscopic instruments for appropriate instruments, warnings and cautions prior to
use. Such sources of energy include electrical, electrohydraulic, electrosurgical, heat hydraulic, laser, light, pressure, sound, ultrasound and vacuum.
• Do not insert or advance the ureteroscope unless there is a clear live endoscopic view of the lumen through which the scope is being advanced (or confirm with
visualization by other imaging modalities).
• During the procedure, if the live endoscopic image is lost, do not advance or insert the ureteroscope and do not insert, advance or actuate accessories.
• Do not use excessive force while advancing or withdrawing the scope. If resistance is felt during advancement or withdrawal of the scope, investigate the source
of resistance and/or take remedial action if necessary.
• Do not force the distal tip of the ureteroscope against the sidewall of the ureter or renal pelvis.
• Do not use excessive force when advancing or withdrawing an accessory within the ureteroscope.
• When inserting or using accessories, maintain continuous visualization of the distal tip. Ensure that the distance between the distal tip of the ureteroscope and
the object in view is greater than the ureteroscope’s minimum visible distance. Failure to do so may result in the accessories causing patient injury.
• Do not withdraw a laser fiber back into the ureteroscope while the laser is firing. Doing so may cause patient injury and/or scope damage.
• Do not look directly into the light emitted from the ureteroscope.
• Verify ground isolation when setting up and using accessories from different manufacturers prior to procedure.
• Do not open the handle of the ureteroscope.
• The ureteroscope is a single-use device and there are no serviceable parts. Do not repair damaged or non-operating ureteroscopes. Do not use the ureteroscope
if damage is discovered or suspected.
• Do not excessively bend the flexible shaft or the articulating section of the ureteroscope.
• If damage to the ureteroscope occurs or it stops functioning during a procedure, stop using the ureteroscope immediately. See troubleshooting section for more
information. Continue the procedure with a new ureteroscope, as appropriate.