Ventrio™ ST Hernia Patch

Self-expanding uncoated monofilament polypropylene patch with SorbaFlex™ Memory Technology and an absorbable barrier based on Sepra® Technology.

Carousel Image
Loading
Overview
false
Features and Benefits

Sepra® Technology in a low profile, lightweight mesh

  • An extensively studied barrier with more than 10 publications and used clinically since 2007.
  • The unique hydrogel barrier swells to minimize tissue attachment to the visceral side of the mesh.
  • Bioresorbable PGA fibers reinforce the integrity of the hydrogel barrier by binding it to the polypropylene mesh.
  • The hydrogel barrier resorbs within 30 days providing visceral protection during the critical healing period.
Efficient

Efficient solution based on Sepra® Technology

  • Unique pocket aids in the proper placement and positioning of the patch.
  • Designed to facilitate the use of mechanical fixation devices and/or sutures.
  • Available in a variety of shapes and sizes to accommodate defect sizes and locations.

 

The Ventrio™ ST Hernia Patch is compatible in both open and laparoscopic ventral procedures with the Optifix™ and SorbaFix Absorbable Fixation Systems, as well as the CapSure and PermaFix Permanent Fixation Systems.

Easy

Easy for laparoscopic repair through a smaller incision

  • Provides the benefits of a laparoscopic repair through the ease of a smaller incision.
  • SorbaFlex™ Memory Technology allows the patch to “spring open,” lay flat to maintain shape, and then fully absorbs over time.
  • Simplifies placement and positioning of the patch throughout the ventral hernia repair.

Intraabdominal placement through a small open incision

  • No preperitoneal lateral dissection may reduce surgical time and lead to quick patient recovery.
  • Minimized dissection may reduce the chance of infection and seroma as well as the need for drains.
  • The unique SorbaFlex™ Memory Technology permits rolling of the patch for easy insertion, allowing the patch to “spring open,” lay flat to maintain shape and then fully absorb over time.

Established technique supported by published clinical data

  • The design of the Ventrio™ ST Hernia Patch allows the use of the familiar CK™/ Ventrio™ Hernia Patch technique for open ventral hernia repair.
  • The technique is peer-reviewed and supported by published clinical data.
Proven1

Proven1  for strong ventral hernia repair

  • Hydrogel barrier is based on Sepra® Technology.
  • Uncoated monofilament polypropylene mesh allows for complete tissue ingrowth leading to a strong repair.
  • Materials have been used in general surgery for years with demonstrated clinical success.2

 

Logarithmic regression curve of mean force of lap-shear strength as a function of time. 74% of the 12-week strength is achieved by 2 weeks post-operatively. 
Ventrio™ ST Hernia Patch Preclinical Results

Ventrio™ ST Hernia Patch Preclinical Results

Initial Implant vs. 2 Weeks

Uncoated Monofilament Polypropylene Mesh

  • Over 40 years of proven results in hernia repair. 
  • Allows a fast fibrotic response for a strong repair. 
  •  Provides a long-term repair with minimized recurrence.

Sepramesh™ IP Composite for smooth, efficient deployment

  •  Hydrogel barrier is based on the Sepra® technology which has more than 10 publications and has been used clinically since 2007. 
  • Unique hydrogel barrier swells to minimize tissue attachment to the visceral side of the mesh.8 
  • The Sepramesh™ IP Composite resorbs within 30 days providing visceral protection during the critical healing process. 
  •  Bioresorbable PGA fibers reinforce the integrity of the hydrogel barrier by binding it to the polypropylene mesh.

SorbaFlex™ memory technology for flexibility and strength

  • Polydioxanone (PDO) monofilament is commonly used in other well-known surgical products (e.g. suture). 
  • Unique in its flexibility and tensile strength, it facilitates patch insertion and proper placement. 
  • Absorption via hydrolysis is essentially complete in 24-32 weeks.

Mechanic Fixation

Reference
false

BD-16949

Products & Accessories
  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 8.7 in x 10.7 in (22.1 cm x 27.1 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 8.7 in x 10.7 in (22.1 cm x 27.1 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Midline, 6.1 in x 10.1 in (15.5 cm x 25.7 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Midline, 6.1 in x 10.1 in (15.5 cm x 25.7 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Large Circle, 4.5 in (11.4 cm) diameter

  • product-image

    Ventrio™ ST Hernia Patch, Large Circle, 4.5 in (11.4 cm) diameter

  • product-image

    Ventrio™ ST Hernia Patch, Small Circle, 3.0 in (7.6 cm) diameter

  • product-image

    Ventrio™ ST Hernia Patch, Small Circle, 3.0 in (7.6 cm) diameter

  • product-image

    Ventrio™ ST Hernia Patch, Medium Oval, 4.3 in x 5.5 in (11.0 cm x 14.0 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Medium Oval, 4.3 in x 5.5 in (11.0 cm x 14.0 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 7.7 in x 9.7 in (19.6 cm x 24.6 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 7.7 in x 9.7 in (19.6 cm x 24.6 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Large Oval, 5.4 in x 7.0 in (13.8 cm x 17.8 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Large Oval, 5.4 in x 7.0 in (13.8 cm x 17.8 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Small Oval, 3.1 in x 4.7 in (8.0 cm x 12.0 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Small Oval, 3.1 in x 4.7 in (8.0 cm x 12.0 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 10.8 in x 13.7 in (27.4 cm x 34.9 cm)

  • product-image

    Ventrio™ ST Hernia Patch, Extra Large Oval, 10.8 in x 13.7 in (27.4 cm x 34.9 cm)

Related Products

References
false
Resources
References
false